276°
Posted 20 hours ago

Qiumi Zigbee Thermostat Radiator Valve, Smart Programmable Thermostat, Temperature Heater, Alexa,Googlehome Voice Control

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

OTA updates are supported but my device doesn't show a firmware version. Maybe someone can help with this. HA Automations

Zigbee Thermostat Radiator Valve, Smart Programmable Qiumi Zigbee Thermostat Radiator Valve, Smart Programmable

A list of all the entities is added, and a Thermostat Card which allows you to set the target temperature. It’s a shame because I actually use dumb TRVs in my home in the US. In some cities there are still lots of old steam radiators in use. But the smart TRVs from danfoss, eurotronic, netatmo and others just aren’t sold here . EF00/026A,CurrentTemperature # (value ignored because isn't a valid tempurature reading. Misdocumented and usage unclear) When a command is received, attributes are published both in their low-level and high-level formats (if known). We are now providing a Zigbee Device plugin mechanisms, using simple text files. These files specify mapping on a per-device type basis. The goal is to fill most of the gap with Zigbee2MQTT (provided that you write the device plugin files). The lightweight nature of plugins permits to load only the plugins required by the devices used, and does not require a sowftare update for new devices. How does it work? ~

Linking to Zigbee2MQTT

You simply copy device plugin files (externsion *.zb) in the file system and they are automatically loaded at start. MQT : tele /% t opic%/RESULT = { "ZbState" :{ "Status" : 20 , "Message" : "Disable Pairing mode" }} If you pair devices such as switches or remotes, you will also receive commands from those devices. In my self-calibration scenario, I applied the calibration script to the TRV 1 and left the other one without offset applied. Thanks to the exchange between the room temperature sensor and the internal sensor of the TRV, I’m able to compare the two values, calculate the correct offset and apply it for the next reporting interval. Yes, if it is zigbee based, it should pair straight to Home Assistant. I am using the ZHA integration with my USB zigbee dongle.

Thermostatic Radiator Valve – MOES

CMD : ZbI nf o 18 : 38 : 51.532 MQT : tele /xxx/SENSOR = { "ZbInfo" :{ "0xECD0" :{ "Device" : "0xECD0" , "Name" : "IKEA_Bulb" , "IEEEAddr" : "0x90FD9FFFFE03B051" , "ModelId" : "TRADFRI bulb E27 WS opal 980lm" , "Manufacturer" : "IKEA of Sweden" , "Endpoints" :[ 1 ], "Config" :[ "O01" , "L01.2" ], "Power" : 1 , "Dimmer" : 160 , "X" : 30138 , "Y" : 26909 , "CT" : 350 , "ColorMode" : 2 , "RGB" : "FFC773" , "RGBb" : "A17E49" , "Reachable" : true , "LastSeen" : 353 , "LastSeenEpoch" : 1658349178 , "LinkQuality" : 79 }}} 18 : 38 : 51.570 MQT : tele /xxxx/SENSOR = { "ZbInfo" :{ "0x8959" :{ "Device" : "0x8959" , "Name" : "Plug" , "IEEEAddr" : "0x7CB03EAA0A0292DD" , "ModelId" : "Plug 01" , "Manufacturer" : "OSRAM" , "Endpoints" :[ 3 ], "Config" :[ "L03.0" , "O03" ], "Dimmer" : 254 , "Power" : 0 , "Reachable" : false , "LastSeen" : 16607299 , "LastSeenEpoch" : 1641742232 , "LinkQuality" : 147 }}} RSL : RESULT = { "ZbSend" : "Done" } 16 : 24 : 02.252 RSL : SENSOR = { "ZbReceived" :{ "0x7120" :{ "Device" : "0x7120" , "Name" : "SHP15" , "Power" : 0 , "Endpoint" : 1 , "LinkQuality" : 229 }}} No. It's either not closing the valve all the way in which case it could be it's physically seized up or the TRV My device was spamming MQTT messages so I had to set a debounce in device config. Reporting I only get clusters Ota and genTime.Countdown in minutes. Value can be found in the published state on the boost_heating_countdown property. It's not possible to read ( /get) or write ( /set) this value. The minimal value is 0 and the maximum value is 15. The unit of this value is min. # Boost heating countdown time set (numeric)

MoesGo Tuya ZigBee3.0 New Mini Radiator Actuator Smart

Secondly they are controlled using node red so work just as they are needed, responding to opened windows or presence at home, sunset times etc. Window status closed or open . Value can be found in the published state on the window property. It's not possible to read ( /get) or write ( /set) this value. If value equals OPEN window is ON, if CLOSED OFF. # ClimateAs you will see in my screenshot below, I have room by room control. I use the Wiser app only to control my hot water on a set schedule (which I never change). Everything else is controlled in Home Assistant. Hi, since a few days, I own four Eurotronic Spirit radiator valves. Till now, I am not so happy with them, but I am not sure if the occurring problems are caused by the spirits or are related to OpenHAB. It seems that quiet a few people around here... EDIT: Ancora non sono sicuro di come calibrarlo correttamente, sembra che il mio radiatore fosse ancora acceso nonostante la posizione fosse 0. Immagino che qualcosa non sia andato per il verso giusto con la calibrazione, quindi questa volta l'ho fatto di nuovo e l'ho avvitato ancora un po 'quando è iniziato ritrarre il servo. Spero solo che non esca di nuovo.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment