A programmer and room thermostat (stat) are used to control heating times and room air temperatures. The programmer and room stat may be combined into a single programmable room stat.

Honeywell V4043H 1056 - 2 Port Motorised Zone Valve 22mm Honeywell V4043H 1056 - 2 Port Motorised Zone Valve 22mm

Drive spindle of a Honeywell motorised valve. It is accessed by removing the valve powerhead. Be warned, with Honeywell motorised valves made pre-1985 you have to drain down first to remove the powerhead! The commonest fault with Honeywell motorised valves is motor failure. Honeywell valve motor fault? Testing a Synchron valve motor Replacing a failed Synchron motor in a Honeywell motorised valve is quite straightforward, assuming you know how to work with mains electricity safely. Make sure you read the whole process through before starting! Honeywell make a large range of motorised valves used in domestic central heating systems. The most common by far are the 22mm 3-port, 5-wire, mid-position valve and the 22mm 2-port, 5-wire, zone valve. These 22mm valves (3-port V4073A1039 and 2-port V4043H1056) are used in smaller and medium sized properties. So the only difference between the two valves is the orange wire on the downstairs is not going live.There are lots of poor quality synchronous motors out there. If the motor cap says “Synchronous” rather than “SYNCHRON ®” it may cost less than half but you’ll probably be changing it again before long!

Honeywell Home 2 Port Zone Valve 22mm | Toolstation

Honeywell 2-port motorised zone valves (V4043H) are electrically quite simple. The powerhead contains the motor, which is used to drive the valve open, and an auxiliary switch or end switch. Honeywell 22mm zone valve operation (V4043H1056) Honeywell say that the manual lever located on the end of the powerhead is not a position indicator and should be used used for filling the system and for draining down only. If the powerhead (actuator) can be safely removed from the valve body (see warning above about pre-1985 Honeywell valves) you can try to turn the spindle. You may need a tool unless you have strong fingers. You must also isolate the electrical supply before removing a Honeywell motorised valve powerhead. which leads me on to why I've posted this topic. When I put the hot water on, the boiler (a 10 year old baxi solo) will run for about 10 mins before the overheat light comes on, followed by banging in the pipes. I basically want to know whether the 2 port valve may be malfunctioning, causing this problem. I had a BG engineer in but all I got from him was "flush the system" so I want to do some detective work myself. The electronics in Honeywell motorised valves tend to be quite stable and show relatively few faults but the motor may fail after years of operation. Honeywell use Synchron motors and these are freely available but there are lots of cheap cloned motors out there. These look identical but, instead of the name SYNCHRON, they use the word Synchronous.With modern boilers, the boiler sends a Live feed to the circulating pump which then pumps heated boiler water through the valve. It will go to the radiators or to the cylinder coil, depending on which valve was opened. With older boilers, the Live from the auxiliary circuit end switch goes directly to the pump at the same time as it goes to the boiler Switched Live.

Honeywell Home 2-Port Motorised Zone Valve 1 Inch BSP

I'm assuming that you've got no hot water due to the overheat malfunction - in which case there's nothing to stop you hooking the valve open permanently if this resolves the banging (and simultaneously getting you some hot water) until we determine why the valve isn't opening. IF it is a faulty valve, these aren't difficult to replace. It may be easier to have the valve set in the manually open position using the manual lever. (See Honeywell Motorised Valve Manual Lever, below.) All our products are guaranteed for a minimum of 1 year (radiators vary - see individual product specifications, copper tube 25 years) but many offer longer warranties from the manufacturer, which you may need to register for. That noise and that bump are diagnostic. They tell us that the valve has moved into the mid-position where both Heating and Hot Water ports are open. If you can make a Honeywell 3-port mid-position valve move into all three of those positions, the valve and controls appear to be wired correctly and the valve appears to be working normally.

Product Options

In normal operation, with a heat-only boiler, central heating water is heated in the boiler and then pumped round the system by a circulating pump. Motorised valves are used to split or divert the flow. The heated water can either be sent to the radiators (or underfloor heating) or to the cylinder coil to heat the domestic hot tap water. The cooled circulating water is then returned to the boiler to be heated again. Both of these genuine SYNCHRON motors work in Honeywell motorised valves. The motors SYNCHRON make specifically for Honeywell come with two blue wires Only when both white and grey wires are energised (and the valve goes to the Heating Only position) can the orange wire get its 230V supply via the valve itself. (Remember, the orange wire can also get 230V from the cylinder stat if it is calling and a hot water program is on.) In larger properties, 28mm valves may be used (the 5-wire 3-port V4073A1088 and the 6-wire 2-port V4043H1106). The 28mm V4043H1106 2-port zone valve has a6 th wire, coloured white. This white wire might not be used. In that case it should be made safe electrically.

Valve 95C-10819 - V4043H Motorised Zone Valve

When Heating is also called for, the white wire is energised and the valve will motor to, and stop in, a mid-position. Power for the boiler is still supplied directly from the cylinder thermostat. The orange valve wire may have a potential of 230V but this is coming from the cylinder stat (to which the orange wire is also connected) and not from the circuitry of the valve.A Switchmaster Midi 3-port valve body with a seized spindle. This motorised valve was also rusting through round the screw in the picture Honeywell powerhead (actuator) jams? Sometimes a powerhead is able to drive the valve only part way open but not far enough for the auxiliary circuit end switch to close. This valve will then not be able to tell the boiler to fire. When a demand comes from the programmer (via the thermostat), the motor is energised and drives the valve open to allow water to pass. When the valve is fully open, a microswitch is operated in the powerhead, connecting the grey wire to the orange wire. This is called closing the switch. It sounds a bit counter-intuitive, but when a switch is closed it is completing the circuit and allowing current to pass; when the switch is opened it is opening a break in the circuit and stops current from passing.