The wires to disconnect are the two wires which run from the motor. On earlier motorised valves, these were both joined to other wires using metal crimps encased in plastic. On more recent valves, one wire is joined with a crimp and the other is wired directly to the electrical components of the valve.

In smaller properties there is usually one programmer which has two channels. One programmer channel controls the heating (radiators or underfloor) and the other programmer channel controls hot water. Where additional zone valves are used there will usually be another programmer or timer. Honeywell motorised valve construction Been researching the subject a bit online and found out that when the central heating is switched on by the controller, it powers the motor which in turn opens the valve plus also triggers a couple of microswitches which instruct the boiler to ignite. Whereas the internal electrics of the 2-port valve are quite simple, the internal electrical controls of the V4073A mid-position valve are more complex. If the powerhead (actuator) can be safely removed from the valve body (see warning above about pre-1985 Honeywell valves) you can try to turn the spindle. You may need a tool unless you have strong fingers. You must also isolate the electrical supply before removing a Honeywell motorised valve powerhead. There are lots of poor quality synchronous motors out there. If the motor cap says “Synchronous” rather than “SYNCHRON ®” it may cost less than half but you’ll probably be changing it again before long!

Guarantee Terms:

The commonest fault with Honeywell motorised valves is motor failure. Honeywell valve motor fault? Testing a Synchron valve motor That noise and that bump are diagnostic. They tell us that the valve has moved into the mid-position where both Heating and Hot Water ports are open. If you can make a Honeywell 3-port mid-position valve move into all three of those positions, the valve and controls appear to be wired correctly and the valve appears to be working normally. Does water HAVE to flow into the CH or the HW system if the pump is working? If so, then one or other of the outlet pipes should be getting hot, but there are times when neither are getting hot and the boiler is not coming on, as though there is no water flow.

Honeywell 2-port motorised zone valves (V4043H) are electrically quite simple. The powerhead contains the motor, which is used to drive the valve open, and an auxiliary switch or end switch. Honeywell 22mm zone valve operation (V4043H1056) Honeywell say that the manual lever located on the end of the powerhead is not a position indicator and should be used used for filling the system and for draining down only.In medium sized or larger properties, using a combi boiler, there may be an additional zone valve external to the boiler which allows the heating to be split into two zones. The Honeywell 22mm Midposition Diverter Valve V4073A1039 has been designed to control the flow of water in domestic central heating systems, where both radiator and hot water cylinder circuits are pumped. It is typically suited for small to medium sized installations.

If, for example, the heating valve is failing in this way, you will get heat round the radiators while the cylinder hot water is being heated too. When the cylinder is up to temperature, the hot water motorised valve closes and no longer tells the boiler to fire, so the heating now stops too. This can cause the valve spindle to seize. It often becomes stiff to turn at first and the valve may give intermittent problems. Eventually, the spindle may become so stiff that the valve motor cannot turn it at all. V4043H1007 is a 2 port, ¾” BSP Female threaded, 5-wire, normally-closed zone valve with an auxiliary end switchA programmer and room thermostat (stat) are used to control heating times and room air temperatures. The programmer and room stat may be combined into a single programmable room stat.

When using two 2-port valves, the control system may be known as a Sundial S Plan system or a Honeywell S Plan system. When a V4073A mid-position valve is set up in a Y-Plan configuration and Hot Water is called for, power to the boiler is provided directly from the cylinder thermostat. The valve is not energised. My first thought was that the boiler wasn't firing up because the micro switch(es) to do so were faulty.

Water

Synchron valve motors can remain energised and hot for many hours a day, all through the winter. They may eventually fail. A failed Synchron valve motor will prevent a 2-port motorised valve from working. The valve won’t be driven open and the end switch will not be made (connected) so power will not be sent on to the boiler or pump. When using a 3-port valve, the control system may be known as a Sundial Y Plan system or a Honeywell Y Plan system. Inside a Honeywell V4073A 3-port motorised valve showing the rubber ball which closes one or other port, never both. Replacing a failed Synchron motor in a Honeywell motorised valve is quite straightforward, assuming you know how to work with mains electricity safely. Make sure you read the whole process through before starting! Some micro switches are required to work which have failed along with the motor, and they are required to work to indicate to boiler the valve has opened.