If a smoke detector is removed from the base and the battery is also removed, the alarm might still hold some residual charge and beep for up to a minute. Pressing the test button for about 10 seconds will discharge the circuitry. The Ei2110e is a Multi-Sensor Fire Alarm that contains two separate sensing elements – optical and heat. Using intelligent software to monitor two diferent byproducts of fire, its response to all fire types is vastly improved over traditional single sensor alarms. The new sensor chamber design intelligent software and the unique dust compensation algorithm also combine to reduce the frequency of nuisance alarms.

Make sure you look after your smoke alarms by changing batteries and testing the unit on a regular basis. We offer free reminder services to ensure you remember to do your alarm test and to change the battery. Here are some common questions we have been asked by our customers about Ei Electronics and Aico (Ei’s UK operation) mains powered smoke alarms and heat alarms through our fire safety forum. The amber light may flash for one of two reasons; firstly it may be indicating the base is in House Code mode (used while setting up new networks of radio-interlinked alarms). House Code mode is automatically exited after 30 minutes or can be manually exited by inserting a screwdriver in the House Code slot and holding the House Code switch until the amber light turns on. Once a solid amber light appears release the switch and the amber light should stop flashing.Additionally, its resistance to false alarms is also increased. This is further enhanced by the unique dust compensation feature that automatically adjusts for any contamination within the optical sensor chamber. This allows Alarm Test, Locate and Hush functions to be performed from floor level. If the Ei2110 is also interconnected to other 2110/160RC Series mains powered alarms, then the whole system can be controlled remotely. For most Ei Electronics mains powered smoke alarms, a replacement kit is available containing a compatible smoke alarm, and in the case of Ei140 and Ei160 alarms, the new head just slides onto the existing base without the need for an electrician. In an interlinked system when one unit detects smoke, all alarms sound. To silence the alarms in case of a false alarm, press the hush button on the unit that has detected the smoke. This will silence all interlinked alarms.

Remove the alarm from its base and press the test button to drain the residual charge. Does the beeping stop? If not, you have a different alarm in the room that is beeping, e.g. a CO alarm with a low battery Up to twenty alarms can be interconnected which will cause all alarms to sound when one unit senses fire.The Ei2110e also has hardwired and wireless (through the Ei100MRF) Remote Control capability, enabling it to be interconnected to and communicate with compatible Alarms and Devices. Up to 12 Alarms and Devices can be interconnected, which will cause all Alarms to sound when one unit senses fire. An interconnected system will enhance early detection and warning of fire. Features Mains powered Ei Electronics smoke and heat alarms require a 230V AC power supply and up to 12 alarms can be hardwire interlinked in one system. One of the Ei168 radio bases flashes amber light every 10 seconds. All other bases in the group are fine. Solution The radio interlinked smoke alarms of the Ei140 series alarms, while having been fitted by an electrician, are not interconnecting. Solution

The memory feature allows an Alarm that has previously activated to be easily identified (the red LED will flash twice every 48s for a 24h period after an alarm activation).Unique dust compensation feature (The alarm automatically adjusts for any contamination within the optical sensor chamber) The E2110e can be interconnected via hardwire or wirelessly with the RadioLINK+ module Ei100MRF (sold separately) enabling it to communicate with compatible Ei Alarms and accessories. Up to 12 devices can be interconnected.

These rechargeable Lithium cells are designed to have a minimum ten-year life and outlast the life of the alarm itself. They provide up to six months alarm operation without mains power.How to stop beeping from Ei / Aico mains powered smoke and heat alarms Ei141, Ei144, Ei146, Ei150, Ei151, Ei154, Ei156, Ei161, Ei164, Ei166 For most Ei Electronics mains powered alarms a replacement kit is available - this contains an original Ei replacement alarm which is compatible with the old system and contains instructions on how to install. The large Test and Hush button on the front of the product allows for safe and easy operation using a cane or a broom.