If you have a central battery system, then most of the above still applies to you. Drop the incoming power to the battery and do the same walk tests. Make a note of any failures etc. However you need to test the whole system all at once. By testing the whole system at once, you are ensuring that the battery can power all the emergency lights for a full 3 hour duration. If you only tested in zones then the battery would not get a full and proper test. This depends on the size and complexity of your building and the time it would take to evacuate. The minimum duration for an emergency escape lighting system is one hour. One hour’s duration should only be used if the premises are evacuated immediately on power supply failure and it is not reoccupied until full capacity has been restored to the batteries. Standby lighting enables normal activities within in building to continue in the event of a mains power failure. Standby lighting is not a legal requirement but is a facility that some buildings may need depending on the use and occupancy of the premises. Emergency lighting is required in premises to enable occupants to escape safely in an emergency situation. BS 5266-1 states that a building must have adequate illumination to support escape and identify firefighting equipment (or any other fire safety equipment). Sometimes there isn’t a test key switch. If not then you have to find the consumer unit and turn off the power to the whole circuit that controls the emergency lights. Hopefully it will be marked which one it is, but it could be more than one circuit.

Annual emergency lighting tests need to be carried out by a professional technician. This will involve testing your system for the full duration – usually three hours – and is commonly paired with testing your fire alarm. If you notice any issues with your system, you should call in a professional technician to diagnose and remedy the situation as soon as possible to ensure you are covered. Emergency lighting is essential for safety in commercial buildings. Whether you manage an office building, a retail unit or a leisure facility, you should have working emergency lighting to help meet the requirements set out in BS 5266:2016, which stipulates the need for buildings to have adequate illumination when mains power fails. The frequency in which you should get your emergency lighting tested can vary depending on system type (i.e. maintained emergency lighting or non-maintained), but as a general guide, you should aim to get your emergency lighting system tested monthly, in addition to an annual ‘full duration’ test as described in BS 5266-1. High risk task area lighting provides light for the safety of people involved in potentially dangerous processes. This lighting enables proper shut-down procedures to be followed for the safety of the operator and other occupants of a building.Yes and no. If it is a small building and all the emergency lights are on one circuit, then yes, you have no choice. However if it is a large building then it would make sense to stagger the testing. This way the whole building would not be affected if there was a power cut, during the recharge time. Testing Central Battery Systems

Be very careful when touching anything inside the electrical consumer box, there is a danger of electrocution if something is wrong. If in doubt seek a qualified electrician ** What time of day should I test the emergency lights Here at the Fire Protection Association, we offer a 5-day Fire Detection, Alarms, and Emergency Lighting training course that provides a comprehensive understanding of systems, legislation, and standards including BS 5266-1 and BS 5839, as well as practical guidance for carrying out installation, commissioning, and maintenance of systems. Find out more here. You need emergency lighting in areas that could be considered “dangerous” such as commercial kitchens or plant rooms. If your building has rooms larger than 60 square metres, then emergency lighting is recommended. How long do emergency lights need to stay on? Emergency lighting testing requirements stipulate that emergency lighting must be maintained and regularly tested in the same way as other emergency equipment. Each light should be identified and have a location identity for recordkeeping. A record log can then be kept of the system test, defects, any damage to the system, and remedial action relating to each light. Standards BS 5266-8:2004 and BS EN 50172:2004 describe the testing of emergency lighting units. MonthlyThere are many different types of emergency lights and different types of emergency lighting test facilities however most of these different pieces of equipment are generally tested and inspected in a similar way. Is your building permanently used E.G. Hotels, then you need to test the lights so that the end of the test corresponds to the start of day. In this way the emergency lights will have a good time to recharge during daylight hours. Natural daylight will help if the emergency lights don’t last 3 hours. Should I test ALL emergency lights at once? UK fire regulations stipulate that your emergency lights should be turned on and off monthly to test them and have a full service once a year. The latest British Standard recommends that you have a 3 hour emergency lighting test once a year, during which your main light circuit should be switched off and your emergency lights left on for a 3 hour period to find out of any batteries need replacing. How can Equiptest help me?

Due to emergency light systems being so important in the process of protecting building occupants and highlighting escape routes and firefighting equipment, it is essential that emergency escape lighting is regularly tested and maintained to ensure that in the event of a failure of mains power, the lighting works correctly and escape routes are effectively illuminated (escape route lighting).This advice and guidance article provides advice on how often you should get your emergency lighting tested, and how to test your emergency lighting. How often should emergency lighting be tested? First and foremost, your emergency lighting must be tested by a competent person due to the important nature of the system in ensuring occupant safety in the event of an emergency. A minimum duration of 3 hours should be used for emergency escape lighting if the premises are not evacuated immediately. The 3 hour time frame allows the fire brigade time to work in the event of a fire after all of the building’s occupants have been safely evacuated. How often should my emergency lighting system be tested? There should be a monthly test of your emergency lighting carried out by the responsible person for your building. This is usually a short test to ensure that your emergency lighting works, making note of any units not working or those that require cleaning and maintenance. We can provide emergency lighting testing and servicing to ensure you are fire safety compliant. We can test your emergency lighting system at a time that suits you. The results of all testing and any necessary corrective action can be recorded in your fire safety logbook. This record is then available for inspection if required.Areas in which there is moving machinery or vehicles, flammable materials or control rooms associated with potentially dangerous processes have, as ‘high risk task areas’, slightly different requirements in relation to emergency lighting – particularly in relation to the illuminance levels to be maintained and duration of operation. High risk task area lighting is provided predominantly to ensure that processes can be safely terminated, and occupants make their evacuation from the area without undue risk from the process. The team here at Fire Trade Supplies have assembled a collection of Fish Key Emergency Lighting including F9099 grid keys (PK6), Multi-EL (3 pairs of assorted EL keys), EL key - crabtree style (PK6) as well as many more combinations which can all be found in our store.